Materials:
Body: PA 66 GF60, seals: NBR, condensate container: polycarbonate

Temperature range:
-10 to +50 °C

Input pressure:
1.5 - 16 bar (model series 0: 1.5 - 12 bar)

Condensate draining:
Semi-automatic** (activated carbon filter without drainage)

Media:
Compressed air, neutral gases

ATEX:
Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU (not model series 0 or differential pressure indicator / differential pressure gauge)

Advantages:
•simple assembly of single components using coupling kits within a model series.

Application:
Microfilters are used where high requirements are required for the purity of the compressed air requirements. Finest particle (> 0,01 µm) and oil mist is separated here. We recommend the upstream connection of a prefilter to increase the service life.

Dust removal:
> 0,01 µm (99,999 %)

Residual oil content:
0.01 mg/m³ (Class 1 according to DIN ISO 8573-1)

Optional:
Version with metal bowl and inspection tube (model series 0: without inspection tube) -M, automatic discharge -AM, automatic discharge closed when not pressurised (0 to 16 bar, model series 0: 0 - 12 bar) -AMNC
Properties
Ver­sion Mi­cro­fil­ter (sub-​microfilter)
Model se­ries Fu­tura 2
Thread G 1/2"
Op­ti­mal flow* [l/min] 450
Con­tainer de­sign Plas­tic con­tainer with pro­tec­tive cage
Con­den­sate drain Semi-​automatic
Max. con­den­sate amount [cm³] 49
H [mm] 195
H1 [mm] 147
L [mm] 63
Mount­ing brack­ets W 2 F
Cou­pling kit KP 2 F
Cou­pling kit with wall con­sole KPW 2 F
Re­place­ment fil­ter X 28/67
Dif­fer­en­tial pres­sure in­di­ca­tor DDA B
Dif­fer­en­tial pres­sure gauge DDA M
input pres­sure [bar] 1,5 - 16
Further information on FX12F
Weight 440 g / pcs
GTIN 4050571311247
Customs duty number 84213925
RoHS compliant Yes
Documents
*at 6 bar input pressure and 0.1 bar pressure loss, **as soon as the inlet pressure falls below the minimum input pressure, the drain valve opens automatically. The semi-automatic drain valve can be prevented from opening by screwing the drain screw tight.

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Immediately available
Payment options:

Cash on delivery

Invoice