Design |
Block structure
|
Complies to standard |
EN 60947-5-2
|
Permission |
RCM mark, c UL us - Listed (OL)
|
CE certificate (see declaration of conformity) |
acc. to EU-EMV Directive, acc. to EU-RoHS Directive
|
Certified awarding point |
UL E232949
|
Material information |
LABS containing materials included, RoHs compliant
|
Measurement principle |
Optoelectronic
|
Detektionsverfahren |
Einweglichtschranke, Empfänger, Sender
|
Light type |
Laser, red
|
Max. light spot |
50 mm bei 20000 mm
|
Range [mm] |
0 bis 20000
|
ambient temperature [°C] |
-40 to 60
|
Control output |
Gegentakt
|
Switching element function |
umschaltbar, NPN hellschaltend, PNP dunkelschaltend
|
Max. switching frequency [Hz] |
1250
|
Max. output current [mA] |
100
|
Voltage drop [V] |
0 to 1.5
|
Timer function |
über IO-Link
|
Short circuit resistance |
Cycling
|
Report |
IO-Link
|
IO-Link, report |
Device V 1.1
|
IO-Link, communication mode |
COM2 (38.4 kBaud)
|
IO-Link, SIO mode support |
yes
|
IO-Link, port type |
A
|
IO-Link, process data width OUT |
1 bit (Emitter), 2 bit (Receiver)
|
IO-Link, process data contents OUT |
1 bit (Emitter disable), 1 bit (Hold)
|
IO-Link, process data width IN |
2 bit (Receiver)
|
IO-Link, process data contents IN |
1 bit (Stability Alarm), 1 bit SSC (Switching Signal)
|
IO-Link, minimum cycle time |
2,3 ms
|
IO-Link, data memory needed [Byte] |
2.000
|
Operating voltage range DC [V] |
10 to 30
|
residual ripple |
10 %
|
Empty run current [mA] |
14
|
Reverse polarity protection |
for all electrical connections
|
Electrical connection 1, connection type |
Plug
|
Electrical connection 1, connection technology |
M8x1 A coded to EN 61076-2-104
|
Electrical connection 1, number of pins / wires |
3
|
Electrical connection 1, fastening type |
Screw lock
|
Plug contacts material |
brass, Gold plated
|
Fastening type |
With Throughway bore for screws M3
|
Torque [Nm] |
0,8
|
installation position |
arbitrary
|
Housing material |
PC, PMMA
|
Operation-readiness display |
LED green
|
Switching status indicator |
LED yellow
|
Setting options |
IO-Link, Teach-In, Potentiometer
|
Protection category |
IP65, IP67, IP69K
|
Insulation voltage [V] |
500
|
Surge voltage strength [kV] |
1
|
Corrosion resistant class KBK |
1 - low corrosion stress
|
Degree of contamination |
3
|
Functional reserve display |
LED gelb blinkend
|
Laser protection class |
1
|