Electric PVC ball valve, Rp 1-1/4", Female thread, FKM-seal
Item number:
KH 114 PVCFK ELI
Example illustration
Item description
Advantages:
•2 additional limit switches,
•torque cut-off,
•variable voltage (DC or AC),
•manual emergency operation,
•integrated heating in actuator housing
Ball valve
Materials:
Body: PVC-U, bridge: PP, seals: EPDM or FKM, ball seat: PTFE
Temperature range:
0 to +60 °C
Operating range:
Industry, water treatment or water supply
Rotary actuator
Description:
Electrical rotary actuator with optical position indicator, manual emergency operation and switch room heating Two additional limit switches are installed for further control requirements. An electronic torque monitoring unit prevents damage in the event of overload. The manual emergency operation can be done without dismantling the external cladding. Do not use upside down!
Materials:
Body: PA 6
Temperature range:
-20 to +70 °C
Voltage:
24 - 240 V AC/DC, (drives can be operated with direct or alternating voltage)
Protection class:
IP 67
Power-on time:
75%
Optional:
Regulating time 140 sec. (only for drive size 2 & 3) -140, "Battery Safety Return" for emergency closing NC (default configuration) or emergency opening NO (conversion with a jumper) when there is a power failure -BSR, Positioning system 0 - 10 V or 4 - 20 mA (conversion with a jumper), precision: 3%, linearity: 2%, hysteresis: 3%, switch position NC or NO (conversion with a jumper) -DPS
Warning:
Not suitable for compressed air or other gases under pressure!
Properties
Volt­age [V] 24 to 240 V (AC/DC)
Seals FKM
Ver­sion Fe­male thread
Thread ball valve Rp 1-1/4"
De­sign (elec­tric drive) Stan­dard
DN [mm] 32
In­stal­la­tion length ball valve [mm] 121
PN [bar] 0 - 16
Flow* [l/min] 1000
Reg­u­lat­ing time [s] 9
Spare dri­ves ELU 230-2
Further information:
Weight 2,6 kg / pcs
GTIN 4050571407971
Customs duty number 84818081
RoHS compliant Yes
Manufacturer Köly
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
As of: 31.03.2025