FUTURA filter regulator, G 3/4", 0,1 to 2 bar, model series 4
Item number:
FR 34-2 F
Example illustration
Item description
Version:
Self-relieving pressure regulator with additional filtering using the centrifugal principle and sintered filter
Materials:
Body: PA 66 GF60, spring hood: POM, diaphragms and seals: NBR, condensate container: polycarbonate
Temperature range:
-10 to +50 °C
Input pressure:
1.5 - 16 bar (model series 0: 1.5 - 12 bar)
Condensate draining:
semi-automatic**
Pressure gauge connection:
G 1/4" (model series 0: G 1/8")
Pore width in the filter:
5 µm
Media:
Compressed air, neutral gases
Advantages:
•Automatic venting in the event of overpressure on the secondary side,
•Easy assembly of individual components using coupling kits within a model series,
•Hand wheel can be locked by pressing down on it and bolted with a lock - please use VHS 20 (model series 0 cannot be locked).
Max. condensate amount:
87 cm³
Switch panel thread:
M 50x1,5
Scope of delivery:
Pressure regulator including 50 mm pressure gauge
Flow:
13000 l/min, secondary relieving: 120 l/min
Own air consumption:
Max. 1,5 l/min
ATEX:
Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU
Optional:
Version with metal bowl and inspection tube -M, automatic discharge -AM, automatic discharge closed when not pressurised (0 to 16 bar) -AMNC, Safety version: with upstream lockable ball valve and filler valve -Si
Properties
Ver­sion Fil­ter reg­u­la­tor
Thread G 3/4"
Pres­sure reg­u­la­tion range [bar] 0,1 - 2
Con­tainer de­sign Plas­tic con­tainer with pro­tec­tive cage
Con­den­sate drain Semi-​automatic
Pres­sure gauge dis­play [bar] 0 - 2.5
Mount­ing brack­ets W 4 F
Cou­pling kit KP 4 F
Cou­pling kit with wall con­sole KPW 4 F
input pres­sure [bar] 1,5 - 16
Further information:
Weight 1,2 kg / pcs
GTIN 4050571306656
Customs duty number 84811005
RoHS compliant Yes
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
As of: 26.03.2025